TITAN-PORT SPECIAL
TITAN-PORT D
DIALYSIS
The TITAN-PORT D allows the repeated alternative vascular access e.g. for veno-venous dialysis for renal insufficiency requiring dialysis
- The use of the associated special port needles is obligatory.
- hypoallergenic
- high biocompatibility
- light weight (<22 g)
- no chemical reactivity with injection solutions
- MR conditional safe up to 3 Tesla
- secure screw closure mechanism between chamber and catheter
- suture holes for fixation to muscle fasciae
- compatible with non-coring port needles
- high pressure stability
- self-sealing
- holds the needle reliable in place
- SFN special puncture needle 15 G – 1.000 punctures; 14 G – 500 punctures
- Polyurethane or silicone: non- knicking or bending material
- single lumen or double lumen catheter
- outstanding biostability
- calibration marks for precise and safe implantation
- radiopaque
- free from latex, PVC and DEHP
- specially optimized catheter design
- catheter and port chamber can be disconnected
TITAN-PORT D (dialysis) is a fully implantable, venous port system
providing as an access option for performing veno-venous dialysis.
There are 2 different systems in complete sets available – The port catheter system with double lumen PU catheter 14 F and the port catheter system with single lumen silicone catheter 12 F:
- Double lumen dialysis port catheter system:
The set includes two identical titanium port chambers with a self-sealing silicone membrane and two screws to fix the catheters to the outflow tubes, and a polyurethane catheter 14 F with an inflow and outflow connection to a port chamber.
Each system is also supplied with two special puncture cannulas SFN 1835 B, a puncture cannula SFN 0930 G, an introducer set (consisting of an 18 G introducer cannula, a 15 F introducer peel-away and a 0.89 mm guide wire), a tunnelizer, the instructions for use and an implant card.
- Single lumen silicone catheter
The set includes a titanium port chamber with a self-sealing silicone membrane and a screw to fix the catheter to the outflow tube and a single lumen silicone catheter with an inflow and outflow connection to the port chamber.
Each system is also supplied with a special puncture cannula SFN 1835 B, a puncture cannula SFN 0930 G, an introducer set (consisting of an 18 G introducer cannula, a 13 F introducer peel-away and a 0.89 mm guide wire), a tunnelizer, these instructions for use and an implant card.
TITAN port catheter systems are MR conditional safe. We will be happy to provide you with further information on request.
The TITAN-PORT D allows repeated vascular access als alternative e.g. for: veno- venous dialysis in dialysis-dependent kidney failure
- either primary
- or as an alternative to failed long term access
- optional for extracorporeal apheresis
The advantage is a low risk of infection, simplified access and considerably improved quality of life for the patient as provided by a closed system.
Intended purpose: The port catheter system is only used to pass blood and medication into or out of the patient’s vascular system. The product itself thus fulfils a physical property and has no medical, therapeutic effect.
Patient group: Patients in need of long-term central venous access to the vascular system.
Operators: Medical professionals (doctors, nurses) with appropriate qualifications.
Art.Nr. | Port | Catheter | PZN | |||||||||
Material | Weidth | Length | Height | Septum Ø | Weight | Volume | Material | French | Volume | |||
111252 D-PU* Haemodialysis | Titan | 24 mm | 36.3 mm | 19.9 mm | 11.5 mm | 21.32 g | 0.66 ml | Polyurethane double lumen | 14 | longer leg: 2.3 ml short leg: 2.1 or 1.9 ml depends on shortening | 01674462 | |
111255 D* Haemodialysis | Titan | 24 mm | 36.3 mm | 19.9 mm | 11.5 mm | 21.32 g | 0.66 ml | Silicone single lumen | 12 | catheter 60cm: 0.49 ml/ 10 cm | 01674166 |
* SET including introducer set and tunnelizer
Only special non-coring port needles should be used to puncture the port membrane.
In order to achieve the blood volume necessary for dialysis purposes, correspondingly large-volume special port needles are required, e.g. SFN 1835 B or DPK 2035.
The needles exhibit a unique bevel and angle at the tip. This prevents punch defects at the membrane when the needle is inserted. Two suitable cannulas are included with each system. Appropriate accessories can be ordered separately if required.
Art.No. | Port needle | PZN | |||||||
Ø mm | Length mm | Gauge | Volume ml | Flow | Puncture frequency | Unit | Extra | ||
SFN 1835 B | 1.8 | 35 | 15 | 0,5 | while hemodialysis ~ 300 ml/min, in gravity 225 ml/min | ~ 1000 | 25 St. | straight, with Luer Lock-Adapter, with tubing | 12363630 |
DPK 2035 | 2.0 | 35 | 14 | 0,3 | while hemodialysis ~ 500 ml/min, in gravity 300 ml/min | ~ 500 | 25 St. | with mandrin + needle free adapter | 02429581 |
The SFN® special port needles are available separately:

Here you can look up all the info and its application in our PDF file.
Here you can find all application videos for our products.